BGVNV - T-AMYL ALCOHOL

Product Identification

Product ID:T-AMYL ALCOHOL
MSDS Date:07/18/1986
FSC:6810
NIIN:00N010345
MSDS Number: BGVNV

Responsible Party
MALLINCKRODT INC,SCIENCE PRODUCTS DIVISION
PARIS BYPASS
PARIS, KY 40361
US

Emergency Phone: 314-982-5000

Info Phone: 314-982-5000

Cage: 62910

Contractor
MALLINCKRODT SPECIALTY CHEMICALS CO
PHILLIPSBURG, NJ 08865 US

Telephone: 908-859-2151

Cage: 62910

Ingredients

T-AMYL ALCOHOL.

CAS: 75-85-4

RTECS: SC0175000

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50 RAT ORAL 1000 MG/KG.
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
OVEREXPOSURE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:VAPORS & MISTS CAUSE IRRITATION.SPLASHES
MAY CAUSE IRRITATION W/ SEVERE PAIN,REDNESS.SKIN:CAUSES
IRRITATION.INGESTION:MAY PRODUCE NARCOTIC EFFECTS W/
HEADACHE,NAUSEA,AND VOMITING.INHALATION:VAPOR S & MISTS ARE IRRIT
TO MUCOUS MEMBRANES& UPPER RESP TRACT.HIGH CONC MAY BE NARCOTIC &
CAUSE HEADACHES,NAUSEA,VOMITING.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

First Aid

First Aid:EYES:WASH W/ PLENTY OF WATER FOR AT LEAST 15 MIN,LIFTING
UPPER & LOWER LIDS OCCASIONALLY.SKIN:REMOVE CONTAM CLOTHING.WASH
WITH SOAP OR MILD DETERGENT AND WATER FOR AT LEAST 15 MIN.GET
MEDICAL ATTN IF IRRITATION DEVELOPS OR PERSISTS.INGESTION:CALL A
PHYSICIAN IMMEDIATELY.INHALATION:REMOVE TO FRESH AIR.IF NOT
BREATHING,GIVE ARTIFICIAL RESP.IF BREATHING IS DIFFICULT,GIVE
OXYGEN.CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:OC
Flash Point:21C,70F
Lower Limits:N/K
Upper Limits:N/K
Extinguishing Media:DRY CHEMICAL,ALCOHOL FOAM OR CARBON DIOXIDE.WATER
MAY BE INEFFECTIVE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .WATER MAY BE USED TO FLUSH SPILLS AWAY FROM
EXPOSURES & TO DILUTE TO NON-FLAMMABLE MIXTURES.
Unusual Fire/Explosion Hazard:ABOVE FLASH POINT,VAPOR-AIR MIXTURES ARE
EXPLOSIVE WITHIN FLAMMABLE LIMITS MENTIONED IN THIS DATA
SHEET.HAZARDOUS DECOMPOSITION PRODUCTS:CO AND CO*2.

Accidental Release

Spill Release Procedures:VENT AREA.REMOVE ALL SOURCES OF IGNIT.CLEAN-UP
PERSONNEL NEED PROT CLOTHING & RESP PROT.CONTAIN & RECOVER LIQ IF
POSS.COLLECT AS HAZ WASTE & ATOMIZE IN A RCRA APPROVED COMBUSTION
CHAMBER OR ABSORB WIT H VERMICULITE,DRY SAND,EARTH OR SIMILAR(SEE
SUPP)
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:STORE IN A COOL,DRY WELL-VENTILATED
LOCATION,AWAY FROM ANY AREA WHERE THE FIRE HAZ MAY BE ACUTE.OUTSIDE
STORAGE IS PREFERRED.
Other Precautions:PROTECT AGAINST PHYSICAL DAMAGE.SEPARATE FROM
OXIDIZING MATERIALS.CONTAINERS SHOULD BE BONDED AND GROUNDED FOR
TRANSFERS TO AVOID STATIC SPARKS.STORAGE AND USE AREAS SHOULD BE NO
SMOKING AREAS.USE NON -SPARKING TYPE TOOLS & EQUIP. (SEE SUPP)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW LEVEL OF CONCERN .
Protective Gloves:WEAR IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BOOTS,LAB COAT,APRON OR COVERALLS TO
PREVENT SKIN CONTACT.
Work Hygienic Practices:N/K
Supplemental Safety and Health
VP:10 MMHG @ 17.2C,63F.AUTOIGNITION TEMPERATURE:437C,819F.SPILL/RELEASE
PROC:MATERIAL FOR DISPOSAL AS HAZARDOUS WASTE IN A RCRA APPROVED
FACILITY.DO NOT FLUSH TO SEWER.OTHER PRECAUTIONS:MAINTAIN AN EY E
WASH FOUNTAIN AND QUICK-DRENCH FACILITIES IN WORK AREA.DO NOT WEAR
CONTACT LENSES WHEN WORKING WITH THIS MATERIAL.

Chemical Properties

Boiling Pt:B.P. Text:102C,216F
Melt/Freeze Pt:M.P/F.P Text:-12C,10F
Decomp Temp:Decomp Text:N/K
Vapor Pres:SEE SUPP
Vapor Density:3.03,AIR=1
Spec Gravity:0.805 (WATER=1)
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID WITH CAMPHOR ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:CARBON DIOXIDE AND CARBON MONOXIDE MAY
FORM WHEN HEATED TO DECOMPOSITION.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .MAY COLLECT AS HAZARDOUS WASTE
AND ATOMIZE IN A RCRA APPROVED COMBUSTION CHAMBER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.